Hydraulic Pressure Station Daily Maintenance and Repair

1. When use hydraulic station, it is necessary to check the status of hydraulic oil to ensure a clean work environment for hydraulic station. If we find that the oil deteriorated, we should immediately replace it with new oil. Usually, the hydraulic station oil needs to have a regular filter, replacement for about once half a year.


2. After Hydraulic station is adapted, any person can not optionally screw all valve handles when it is being used or stopping.


3. When we connect the electromagnetic reversing valve, we should be strictly in accordance with the provisions of the voltage and current for matching, and we will operate the corresponding switches for several times to check action flexibility, reliability.


4. Oil tank liquid level should be kept high enough to make the oil have enough cooling conditions and keep the oil tank and oil pipe clean to facilitate heat dissipation.


5. If there is a back oil filter system, Filter (about a month), it should be cleaned regularly about once a month to prevent clogging of the oil return, Severe cases can cause rupture of hydraulic components or oil pump.


6. If there is a water cooling system, cooling water should be remained adequate and pipe should be patency. Air cooler system should maintain proper ventilation to prevent high oil temperature.


7. The system working pressure is to adjust the output pressure of the hydraulic pump by adjusting pressure valve. In general, the pressure adjusted can not exceed the rated pressure of the original design, otherwise it is possible to damage the hydraulic pump, or cause the phenomenon of hydraulic valve stucking or motor being burned out.